Fehlerliste

  • Netzteile
    Fehler ID Fehlername
    bb READY FOR POWER ON
    lb POWER OK
    14 EXTERNAL COMPONENT WARNING
    15 CONTROL VOLTAGE TEMP. WARNING
    16 SOFTSTART-FAULT
    17 POWER OFF WITH BUS SHORTING
    18 HEATSINK OVERTEMP. FAULT
    20 BLEEDER OVERLOAD
    23 DRIVE FAULT
    24 EXTERNAL COMPONENT ERROR
    25 REGEN. POWER OVERLOAD
    26 BUS POWER OVERLOAD
    50 HEATSINK TEMP. WARNING
    52 BLEEDER OVERLOAD WARNING
    60 OVERCURRENT
    69 +24 V / ±15 V / +5 V FAULT
    80 SHORT TO GROUND
    81 POWER FAILURE
    82 PHASELOSS FAULT
    83 LINE VOLTAGE FAULT
    84 MISWIRING
    85 LINE FREQUENCY FAULT
    87 CONTROL VOLTAGE SUPPLY FAILURE
    94 CHECKSUM ERROR
    .. DEVICE FAILURE
    __ +5 V FAILURE
  • Laufwerke
    Fehler ID Fehlername
    F207 Switching to uninitialized operation mode
    F208 UL The motor type has changed
    F209 PL Load parameter default values
    F218 Amplifier overtemp shutdown
    F219 Motor overtemp shutdown
    F221 Error Motor temp surveillance defective
    F226 Undervoltage in power section
    F228 Excessive deviation
    F229 Motor encoder failure: quadrant error
    F233 External power supply error
    F236 Excessive position feedback difference
    F237 Excessive position command difference
    F242 External encoder failure: signal too small
    F245 External encoder failure: quadrant error
    F248 Low battery voltage
    F249 Master drive encoder failure: signal too small
    F252 Master drive encoder failure: quadrant error
    F253 Incr encoder emulator: pulse frequency too high
    F254 Incr encoder emulator: hardware fault
    F255 External power supply DAE 02 error
    F267 Erroneous internal hardware synchronization
    F268 Brake fault
    F270 Error power supply home switch
    F271 Error power supply travel limit switch
    F272 Error power supply probe input
    F273 Error power supply E-Stop
    F276 Absolute encoder out of allowed window
    F280 Short circuit to earth
    F316 Softstart fault power supply unit
    F318 Heatsink overtemp fault power supply unit
    F320 Bleeder overload
    F360 Overcurrent power supply unit
    F369 +24V/+-15V/+5V fault power supply unit
    F380 Short to ground power supply unit
    F381 Mains failure
    F382 Mains phase loss fault
    F383 Line voltage fault
    F384 Connection error at power supply unit
    F385 Line frequency fault
    F394 Checksum error power supply unit
    F401 Double MST error shutdown
    F402 Double MDT error shutdown
    F403 Invalid communication phase shutdown
    F404 Error during phase progression
    F405 Error during phase regression
    F406 Phase switching without ready signal
    F434 Emergency-Stop
    F629 Positive travel limit exceeded
    F630 Negative travel limit exceeded
    F634 Emergency-Stop
    F643 Positive travel limit switch detected
    F644 Negative travel limit switch detected
    F822 Motor encoder failure: signal too small
    F827 Drive interlock while drive activated
    F860 Overcurrent: short in power stage
    F861 Overcurrent: short to ground
    F869 +/-15Volt DC error
    F870 +24Volt DC error
    F871 +10Volt DC error
    F878 Velocity loop error
    F879 Velocity limit S-0-0091 exceeded
    E219 Warning Drive temp surveillance defective
    E221 Warning Motor temp surveillance defective
    E225 Motor overload
    E226 Undervoltage in power section
    E247 Interpolation velocity = 0
    E248 Interpolation acceleration = 0
    E249 Positioning velocity S-0-0259 > S-0-0091
    E250 Drive overtemp prewarning
    E251 Motor overtemp prewarning
    E253 Target position out of travel zone
    E255 Feedrate-override S-0-0108 = 0
    E257 Continuous current limit active
    E259 Command velocity limit active
    E261 Continuous current limit prewarning
    E263 Velocity command value > limit S-0-0091
    E324 Option module error power supply unit
    E325 Recovery overload power supply unit
    E326 Bus power overload
    E350 Heat sink overtemp warning power supply unit
    E352 Bleeder overload warning power supply unit
    E353 Diagnostic message power supply erroneous
    E387 Control voltage supply fault power supply unit
    E410 Slave not scanned or adress 0
    E825 Overvoltage in power stage
    E826 Undervoltage in power section
    E829 Positive position limit exceeded
    E830 Negative position limit exceeded
    E834 Emergency-Stop
    E843 Positive limit switch activated
    E844 Negative limit switch activated
    C100 Communication phase 3 transition check
    C101 Invalid communication parameter (S-0-0021)
    C104 Config IDN for MDT not configurable
    C105 Configurated length > max length for MDT
    C106 Config IDN for AT not configurable
    C107 Configurated length > max length for AT
    C108 Time slot parameter > Sercos cycle time
    C109 Position of data record in MDT (S-0-0009) even
    C110 Length of MDT (S-0-0010) odd
    C111 ID9 + Record length - 1 > length MDT (S-0-0010)
    C112 TNcyc (S-0-0001) or TScyc (S-0-0002) error
    C113 Relation TNcyc (S-0-0001) to TScyc (S-0-0002) error
    C114 T4 > TScyc (S-0-0002) - T4min (S-0-0005)
    C115 T2 too small
    C200 Communication phase 4 transition check
    C201 Invalid parameter(s) (->S-0-0022)
    C202 Parameter limit error (->S-0-0022)
    C203 Parameter calculation error (->S-0-0022)
    C204 Motor type P-0-4014 incorrect
    C210 External feedback required (->S-0-0022)
    C211 Invalid feedback data (->S-0-0022)
    C212 Invalid amplifier data (->S-0-0022)
    C213 Position data scaling error
    C214 Velocity data scaling error
    C215 Acceleration data scaling error
    C216 Torque/force data scaling error
    C217 Motor feedback data reading error
    C218 External feedback data reading error
    C220 Motor feedback initializing error
    C221 Ext feedback initializing error
    C223 Input value for max range too high
    C225 Coprocessor not ready for initialization
    C226 Coprocessor acknowledge failed
    C227 Modulo range error
    C228 Controller type S-0-0140 wrong
    C231 Emulator not loadable
    C232 Motor encoder interface not present
    C233 External encoder interface not present
    C234 Encoder combination not possible
    C235 Load-side motor encoder with inductance motor only
    C236 Motor feedback required (P-0-0074)
    C300 Set absolute measuring
    C302 Absolute measuring system not installed
    C400 Command: switch to parameter mode
    C401 Drive active, switching not allowed
    C402 Only allowed without master
    C500 Reset class 1 diagnostic, error reset
    C501 Error delet only in parameter mode
    C600 Drive controlled homing procedure command
    C601 Homing only possible with drive enable
    C602 Distance home switch - reference mark erroneous
    C604 Homing of absolute encoder not possible
    C700 Basic load
    C701 Basic load not possible if drive is enabled
    C702 Default parameters not available
    C703 Default parameters invalid
    C704 Parameters not copyable
    C705 Locked with password
    C800 Default parameter load
    C801 Parameter default value erroneous (-> S-0-0021)
    C802 Locked with password
    D300 Command adjust commutation
    D301 Drive not ready for commutation command
    D500 Command 'get mark position'
    D501 Incremental encoder required
    D600 Cancel reference point procedure command
    D700 Parking axis command
    D800 Command measuring wheel operation mode
    D801 Measuring wheel operation not possible
    D802 Operation mode cancelled